Hikvision DS-2TD2617-10/PA Termisk PoE

Anbefalet af vores teknikere
5.249,00  m/Moms
( 4.199,20  u/Moms )
Lager: Leveringstid er 7-10 dage
Har du spørgsmål til produktet?
Bare giv os et kald på 70701009

Genialt dobbelt-linse termisk kamera til at sikre et området mod ubudne gæster eller ildebrand.

  • Intet forbliver uset - opdag dem på det termiske- og genkend dem på det visuelle billede.
  • Vær din egen alarmcentral - menneske, køretøj eller ildebrand, få besked direkte på telefonen.
  • Hvidt spotlys og højtaler byder folk velkommen eller  skræmmer ubudne gæster
  • Gem hændelser på en optager eller direkte i kameraet med et hukommelseskort.
Thermal Module  
Image Sensor Vanadium Oxide Uncooled Focal Plane Arrays
Resolution 160 × 120 (the resolution of output image is 320 × 240)
Pixel Interval 17μm
Response Waveband 8 μm to 14 μm
NETD (Noise Equivalent Temperature Difference) ≤ 40 mk (25 °C,F# = 1.1)
Focal Length 9.7 mm
IFOV 2.74 mrad
Field of View 15.96° × 12° (H × V)
Min. Focusing Distance 1.2 m
Aperture F 1.1
Digital Zoom ×2, ×4, ×8
Optical Module  
Image Sensor 1/2.7" Progressive Scan CMOS
Resolution 2688 × 1520
Min. Illumination Color: 0.0089 Lux @(F1.6, AGC ON), B/W: 0.0018 Lux @(F1.6, AGC ON)
Shutter Speed 1 s to 1/100,000 s
Focal Length 8 mm
Field of View 39.42° × 22.14° (H × V)
Aperture F1.6
WDR 120 dB
Image Effect  
Picture in Picture Display partial image of thermal channel on the full screen of optical channel
Bi-spectrum Image Fusion Display the details of optical channel on thermal channel
Target Coloration Yes. Supported in white hot and black hot mode.
Smart Function  
VCA (Video Content Analysis) 4 VCA rule types (line crossing, intrusion, region entrance, and region exiting), up to 8 VCA rules in total.
Temperature Measurement 3 temperature measurement rule types, 21 rules in total (10 points, 10 areas, and 1 line).
Temperature Range -20 °C to + 150 °C (-4 °F to + 302°F)
Temperature Accuracy ± 8 °C (± 14.4 °F)
Fire Detection Dynamic fire detection, up to 10 fire points detectable.
Illuminator  
IR Distance Up to 40 m
IR Intensity and Angle Automatically adjusted
Audible and Visual Alarm  
White Light Range Up to 40 m
Visual Alarm Yes. White light used as the visual alarm, flashing frequency adjustable
Audio alarm Yes. 6 audio alarms are supported to cover all kinds of alarm.
Video & Audio  
Main Stream Optical channel 50 HZ: 25 fps (2688 × 1520, 1920 × 1080, 1280 × 720) 60 HZ: 30 fps (2688 × 1520, 1920 × 1080, 1280 × 720) Thermal channel 25fps (1280 × 720, 704 × 576, 640 × 480, 352 × 288, 320 × 240)
Sub-stream Optical channel 50 HZ: 25fps (704 × 576, 352 × 288, 176 × 144) 60 HZ: 30fps (704 × 480, 352 × 240, 176 × 120) Thermal channel 25fps (704 × 576, 352 × 288, 320 × 240)
Video Compression Main Stream: H.265/H.264 Sub-Stream: H.265/H.264/MJPEG
Audio Compression G.711u/G.711a/G.722.1/MP2L2/G.726/PCM
Network  
Protocols IPv4/IPv6, HTTP, HTTPS, 802.1x, Qos, FTP, SMTP, UPnP, SNMP, DNS, DDNS, NTP, RTSP, RTCP, RTP, TCP, UDP, IGMP, ICMP, DHCP, PPPoE
Network Storage MicroSD/SDHC/SDXC card (up to 256 G) local storage, and NAS (NFS, SMB/CIFS), auto network replenishment (ANR)
API ISAPI, HIKVISION SDK, third-party management platform, ONVIF (Profile S, Profile G, Profile T)
Simultaneous Live View Up to 20 channels
User/Host Level Up to 32 users, 3 levels: Administrator, Operator, User
Security User authentication (ID and PW), MAC address binding, HTTPS encryption, IEEE 802.1x(EAP-MD5, EAP-TLS), access control, IP address filtering
Client iVMS-4200, Hik-Connect
Web Browser Live view (plug-in allowed) : Internet Explorer 11 Live view (plug-in free) : Chrome 57.0 +, Firefox 52.0 + Local service : Chrome 57.0+, Firefox 52.0 +
Interface  
Alarm Input 2-ch inputs (0-5 VDC)
Alarm Output 2-ch relay outputs, alarm response actions configurable
Alarm Action SD record/relay output/smart capture/FTP upload/email linkage/audio alarm/white light alarm
Audio Input 1, 3.5 mm Mic in/Line in interface Line input: 2 to 2.4 V [p-p], output impedance: 1 KΩ ± 10%
Audio Output Linear level, impedance: 600 Ω
Communication Interface 1, RJ45 10 M/100 M self-adaptive Ethernet interface 1, RS-485 interface
General  
Menu language 32 languages English, Russian, Estonian, Bulgarian, Hungarian, Greek, German, Italian, Czech, Slovak, French, Polish, Dutch, Portuguese, Spanish, Romanian, Danish, Swedish, Norwegian, Finnish, Croatian, Slovenian, Serbian, Turkish, Korean, Traditional Chinese, Thai, Vietnamese, Japanese, Latvian, Lithuanian, Portuguese (Brazil)
Power 12 VDC ± 20%, two-core terminal block PoE (802.3af, class 3)
Power Consumption 12 VDC ± 20%: 0.65 A, max. 7.5 W PoE (802.3af, class 3): 42.5 V to 57 V, 0.14 A to 0.22 A, max. 8 W
Working Temperature/Humidity Temperature: -40 °C to 65 °C (-40 °F to 149 °F) Humidity: 95% or less
Protection Level IP66 Standard TVS 6000V lightning protection, surge protection, voltage transient protection
Dimensions 358.3 mm × 113.5 mm × 115.2 mm (14.10" × 4.47" × 4.53")
Weight Approx. 1.76 kg (3.88 lb)

Der er endnu ikke nogen anmeldelser her. Vi vil være glade for hvis du vil anmelde som den første.

Tilføj anmeldelse:

Termiske kamera har 3 primære fordele - sikring af perimeter, sikring mod ildebrand og overvågning af temperatur. Disse kamera har dog endnu en ting der er værd at nævne, nemlig et ekstra indbygget kamera. Serien kaldes derfor også for bi-spectrum, fordi den opfanger både det termiske spektrum og det visuelle.

Kameraet har med sine to linser, rigtig god mulighed for, at beskytte mod enten brand- og røgudvikling, mod ulovligt indtrængen og afvigende temperatur. Den termiske linse sikre dig meget præcise beskeder/alarmeringer og det indbyggede relæ gør det muligt at tilknytte kameraet til de fleste typer tyverialarmer og kontrolcentraler.

Når man sætter kameraet op vælger man om det skal kunne "Adfærdsanalyse (perimetersikring) + måling temperatur" eller "Detektering af brand + måling af temperatur"

Adfærdsanalyse (perimetersikring)
Man kan vælge hvad kameraet skal analysere på, hvor det skal gøre det og i hvilke perioder, samt hvordan det skal reagere såfremt en regel overtrædes

Sikring mod ildebrand
Overvågning mod brand kræver ikke meget opsætning, som vist i videoen herunder, da kameraet har en indstilling til præcis dette formål.

Højtaleren gør det muligt, at advare folk om området om den forestående brand eller røgudvikling. 

Det termiske kamera er ofte brugt til at beskytte mod ildspåsættelse på f.eks. skoler, institutioner, fabrikker, byggepladser mm. da den kan give besked lang tid før et konventionelt brandmeldersystem. Kameraet må dog ikke bruges som erstatning for et konventionelt og godkendt system, da det (endnu) ikke er godkendt at brandmyndighederne. Men f.eks. i en hestestald med hø og andet brandbart materiale, vil det kunne betyde forskellen på liv og død da branden vil kunne blive detekteret i den spæde start, hvilket giver mulighed for at håndtere situationen i tide.

 

Termisk kamera kan sikre mod brand
Termisk kamera til perimetersikring Bi-Spectrum

 

Den dynamiske analyse reagere på flammernes og varmens udvikling.

Måling af temperatur:
Kameraet er også velegnet til at måle temperaturer, i tilfælde der ikke har med brand at gøre - eksempelvis temperaturer i serverrum, maskinrum, eltavler mm.

spacer