• Jablotron JA-100KR-LAN Central / built-in LAN transmitter and radio module
Zoom

Jablotron JA-100KR-LAN Central / built-in LAN transmitter and radio module

Model: JA-100KR-LAN
Availability: In stock In stock - ships within 1 to 2 weekdays In stock In stock - ships within 1 to 2 weekdays
Log in here to buy

JA-100KR is a central in the JABLOTRON JA-100 series, which primarily caters to private installations, e.g. in normal house or in a small business. The device is set up and set up via F-Link software.

JA-100K:
- up to 32 wireless or wired BUS devices
- up to 32 user codes
- up to 4 areas
- up to 4 programmable outputs (PG)
- up to 3 radio modules
built-in LAN
- 10 independent calendars
- reports from the system to 8 users via SMS
- 8 users have the option of voice and SMS report
- 4 selectable special codes for KC (with individual ID)

The printout has a built-in LAN transmitter, which makes communication with MyJablotron, MyCompany and to KC possible. In addition, the control panel also has a JA-111R radio module, and it is also possible to expand with a JA-190Y GSM module if desired.

NOTE special control panel for this control panel

The JA-100 is different from the JA-101 and JA-106 in the following areas:
Only JA-150E and JA-110E control panels can be used for the control panel
- Only one exit / entry delay
- New zone type 'Garage door' extends entry / exit time;
- The exit time is extended even if the 'Garage door' is closed when connected
- The entry time is determined by whether it is a 'delayed' or 'garage door' zone that is opened
- The entry time is not extended if the 'delayed' zone starts it, and the 'garage door' is subsequently opened during the entry time
- Users can not be added in PG outputs, they are added in the internal settings on BP / bypass
- The JA-150E can control multiple PG outputs
- JA-150E does not have the option 'Indicates / checks PG'
- The JA-123E can only control one PG output
- The PG Activation column is removed on the Devices tab
- PG activation of devices is set in the internal settings of the PG output
- Limited possibilities for PG outputs 'reaction to' i.a. lacks the ability to invert an output with 'system event'
- The reaction 'Second PG' is missing - it limits simple door control considerably
- PG output function limited to 'Enable / disable' 'Impulse' and 'copy'
Missing PG output functions: 'delayed copy', 'extended copy' and 'change'
- No possibility of time limitation of users
- 4/6 digit codes - not 8 digits, not prefix
- One card per. user
- No Message A / B / C / D zone type
- No Repetition Zone Type
- 10 calendar events

Technical specifications
excitement ~ 230 V / 50 Hz, T200 mA fuse 250V, 5 x 20 mm ~ 115 V / 60 Hz, T400 mA fuse 250V, 5 x 20 mm
Operating voltage range ~ 195 V ÷ 250 V ~ 110 V ÷ 120 V
Power supply Max 23 VA / 0.1 A
Back-up battery 12 V; 2.6 Ah max.
Maximum battery charging time 48 ÷ 72 hours
BUS voltage / max. Voltage rib 12.0 ÷ 13.8 VDC / ± 100 mV
Max. Number of units 20
Classification of the alarm system Safety class 2 / environmental class II
Operating temperature -10 ° C to + 40 ° C
Humidity Relative humidity 75%, no condensation
excitement Type A - primary supply with a charged backup battery
Dimensions (mm) 268 x 225 x 83
Weight 1450 g

View full description