facebook

Hikvision DS-2TD2617-10 / PA Thermal PoE

Recommended by our technicians
5.249,00  Incl. VAT
( 4.199,20  Excl. VAT )
Availability: Leadtime is 7-10 day(s) Leadtime is 7-10 day(s)
Do you have questions about the product? +45 70701009

Ingenious dual-lens thermal camera to secure an area against uninvited guests or fire.

  • Nothing remains unseen - discover them on the thermal - and recognize them on the visual image.
  • Be your own alarm center - human, vehicle or fire, get notified directly on the phone.
  • White spotlight and speaker welcome people or scare uninvited guests
  • Store events on a recorder or directly in the camera with a memory card.
Thermal Module  
Image Sensor Vanadium Oxide Uncooled Focal Plane Arrays
Resolution 160 × 120 (the resolution of output image is 320 × 240)
Pixel Interval 17μm
Response Waveband 8 μm to 14 μm
NETD (Noise Equivalent Temperature Difference) ≤ 40 mk (25 °C,F# = 1.1)
Focal Length 9.7 mm
IFOV 2.74 mrad
Field of View 15.96° × 12° (H × V)
Min. Focusing Distance 1.2 m
Aperture F 1.1
Digital Zoom ×2, ×4, ×8
Optical Module  
Image Sensor 1/2.7" Progressive Scan CMOS
Resolution 2688 × 1520
Min. Illumination Color: 0.0089 Lux @(F1.6, AGC ON), B/W: 0.0018 Lux @(F1.6, AGC ON)
Shutter Speed 1 s to 1/100,000 s
Focal Length 8 mm
Field of View 39.42° × 22.14° (H × V)
Aperture F1.6
WDR 120 dB
Image Effect  
Picture in Picture Display partial image of thermal channel on the full screen of optical channel
Bi-spectrum Image Fusion Display the details of optical channel on thermal channel
Target Coloration Yes. Supported in white hot and black hot mode.
Smart Function  
VCA (Video Content Analysis) 4 VCA rule types (line crossing, intrusion, region entrance, and region exiting), up to 8 VCA rules in total.
Temperature Measurement 3 temperature measurement rule types, 21 rules in total (10 points, 10 areas, and 1 line).
Temperature Range -20 °C to + 150 °C (-4 °F to + 302°F)
Temperature Accuracy ± 8 °C (± 14.4 °F)
Fire Detection Dynamic fire detection, up to 10 fire points detectable.
Illuminator  
IR Distance Up to 40 m
IR Intensity and Angle Automatically adjusted
Audible and Visual Alarm  
White Light Range Up to 40 m
Visual Alarm Yes. White light used as the visual alarm, flashing frequency adjustable
Audio alarm Yes. 6 audio alarms are supported to cover all kinds of alarm.
Video & Audio  
Main Stream Optical channel 50 HZ: 25 fps (2688 × 1520, 1920 × 1080, 1280 × 720) 60 HZ: 30 fps (2688 × 1520, 1920 × 1080, 1280 × 720) Thermal channel 25fps (1280 × 720, 704 × 576, 640 × 480, 352 × 288, 320 × 240)
Sub-stream Optical channel 50 HZ: 25fps (704 × 576, 352 × 288, 176 × 144) 60 HZ: 30fps (704 × 480, 352 × 240, 176 × 120) Thermal channel 25fps (704 × 576, 352 × 288, 320 × 240)
Video Compression Main Stream: H.265/H.264 Sub-Stream: H.265/H.264/MJPEG
Audio Compression G.711u/G.711a/G.722.1/MP2L2/G.726/PCM
Network  
Protocols IPv4/IPv6, HTTP, HTTPS, 802.1x, Qos, FTP, SMTP, UPnP, SNMP, DNS, DDNS, NTP, RTSP, RTCP, RTP, TCP, UDP, IGMP, ICMP, DHCP, PPPoE
Network Storage MicroSD/SDHC/SDXC card (up to 256 G) local storage, and NAS (NFS, SMB/CIFS), auto network replenishment (ANR)
API ISAPI, HIKVISION SDK, third-party management platform, ONVIF (Profile S, Profile G, Profile T)
Simultaneous Live View Up to 20 channels
User/Host Level Up to 32 users, 3 levels: Administrator, Operator, User
Security User authentication (ID and PW), MAC address binding, HTTPS encryption, IEEE 802.1x(EAP-MD5, EAP-TLS), access control, IP address filtering
Client iVMS-4200, Hik-Connect
Web Browser Live view (plug-in allowed) : Internet Explorer 11 Live view (plug-in free) : Chrome 57.0 +, Firefox 52.0 + Local service : Chrome 57.0+, Firefox 52.0 +
Interface  
Alarm Input 2-ch inputs (0-5 VDC)
Alarm Output 2-ch relay outputs, alarm response actions configurable
Alarm Action SD record/relay output/smart capture/FTP upload/email linkage/audio alarm/white light alarm
Audio Input 1, 3.5 mm Mic in/Line in interface Line input: 2 to 2.4 V [p-p], output impedance: 1 KΩ ± 10%
Audio Output Linear level, impedance: 600 Ω
Communication Interface 1, RJ45 10 M/100 M self-adaptive Ethernet interface 1, RS-485 interface
General  
Menu language 32 languages English, Russian, Estonian, Bulgarian, Hungarian, Greek, German, Italian, Czech, Slovak, French, Polish, Dutch, Portuguese, Spanish, Romanian, Danish, Swedish, Norwegian, Finnish, Croatian, Slovenian, Serbian, Turkish, Korean, Traditional Chinese, Thai, Vietnamese, Japanese, Latvian, Lithuanian, Portuguese (Brazil)
Power 12 VDC ± 20%, two-core terminal block PoE (802.3af, class 3)
Power Consumption 12 VDC ± 20%: 0.65 A, max. 7.5 W PoE (802.3af, class 3): 42.5 V to 57 V, 0.14 A to 0.22 A, max. 8 W
Working Temperature/Humidity Temperature: -40 °C to 65 °C (-40 °F to 149 °F) Humidity: 95% or less
Protection Level IP66 Standard TVS 6000V lightning protection, surge protection, voltage transient protection
Dimensions 358.3 mm × 113.5 mm × 115.2 mm (14.10" × 4.47" × 4.53")
Weight Approx. 1.76 kg (3.88 lb)

There is no reviews yet. Be the first to write us your opinion

Add review:

Den professionelle måde at levere strøm, til et PoE-kamera, er gennem netværkskablet.

På den måde behøver man kun at trække et enkelt kabel til hvert kamera - og skal ikke døje med 230V og små strømforsyninger.

Strømmen til kameraet leveres gennem netværkskablet fra enten...

  • en optager med indbygget PoE, også kaldet NVR. Et typisk valg for installationer op til og med 8 kameraer.
  • en PoE-switch. Populært fortalt en fordelerdåse til netværkskabler. Det typiske valg på store installationer eller hvis man ønsker fleksibel kabelføring.
  • en PoE-injector. Kan kun levere strøm til et kamera.

Af samme grund følger der ikke strømforsyning med PoE-kameraer. Du kan bestille en klassisk strømforsyning her, hvis du ikke ønsker at benytte PoE.

Thermal camera has 3 main advantages - protection of perimeter, protection against fire and monitoring of temperature. However, these cameras have another thing worth mentioning, namely an extra built-in camera. The series is therefore also called bi-spectrum because it captures both the thermal spectrum and the visual.

With its two lenses, the camera has a very good opportunity to protect against either fire and smoke development, against illegal intrusion and deviating temperature. The thermal lens ensures you very precise messages / alarms and the built-in relay makes it possible to connect the camera to most types of burglar alarms and control centers.

When setting up the camera, you choose whether it should be able to "Behavior analysis (perimeter protection) + measurement temperature" or "Fire detection + temperature measurement"

Behavioral analysis (perimeter protection)
You can choose what the camera should analyze, where it should do so and in what periods, as well as how it should react if a rule is violated

Protection against fire
Fire surveillance does not require much setup, as shown in the video below, as the camera has a setting for exactly this purpose.

The speaker makes it possible to warn people about the area about the impending fire or smoke development.

The thermal camera is often used to protect against arson on e.g. schools, institutions, factories, construction sites etc. as it can give notice long before a conventional fire alarm system. However, the camera must not be used as a replacement for a conventional and approved system, as it has not (yet) been approved by the fire authorities. But e.g. in a horse stable with hay and other combustible material, it could mean the difference between life and death as the fire could be detected in the infancy, which allows to handle the situation in time.

Video

The dynamic analysis responds to the evolution of the flames and heat.

Measurement of temperature :
The camera is also suitable for measuring temperatures, in cases that have nothing to do with fire - for example temperatures in server rooms, engine rooms, switchboards and more.

Den professionelle måde at levere strøm, til et PoE-kamera, er gennem netværkskablet.

På den måde behøver man kun at trække et enkelt kabel til hvert kamera - og skal ikke døje med 230V og små strømforsyninger.

Strømmen til kameraet leveres gennem netværkskablet fra enten...

  • en optager med indbygget PoE, også kaldet NVR. Et typisk valg for installationer op til og med 8 kameraer.
  • en PoE-switch. Populært fortalt en fordelerdåse til netværkskabler. Det typiske valg på store installationer eller hvis man ønsker fleksibel kabelføring.
  • en PoE-injector. Kan kun levere strøm til et kamera.

Af samme grund følger der ikke strømforsyning med PoE-kameraer. Du kan bestille en klassisk strømforsyning her, hvis du ikke ønsker at benytte PoE.