Model: JA-150TP

JA-150TP is a wireless thermostat from Jablotron, which in collaboration with a programmable output module, gives full control over the temperature in the home. Via the MyJablotron app, or website, it is possible to remotely control and monitor the temperature. Here you can also see graphs of the temperature history, get reports of overheating or freezing, turn down the heat if a window is open, possibility to maintain a minimum temperature, set up a weekly calendar mode etc.

There is room for 16 thermostats per system and there is also the option of manual temperature control if desired.

Technical specifications
excitement 2 AA Alkaline batteries (LR6) 1.5 V 2400 mAh
Battery life Approx. 2 years
Frequency 868.1 MHz, JABLOTRON protocol
Range Approx. 300 m - open terrain
Recommended installation height 1.5 m above the floor
Operating temperature -10 to + 70 ° C
Accuracy in operating temperatures 0.1 ° C
Dimensions 66 x 90 x 22 mm
Model: JA-150EM-DIN

JA-150EM-D I is a wireless module that can be installed on a DIN rail, which then reads impulses from an electricity meter and transfers readings to the MyJablotron app and web self-service.

This is done via a transmitter contained in the module, which wirelessly transmits information from the electricity meter via the alarm to MyJablotron.

The impulse converter has galvanically separated circuits for 4 kV, and is supplied directly from the switchboard. The converter can be set to a standard pulse output, on an SO electric meter. The unit can differentiate between two types of input (can be connected to the voltage control input). The module has an independent input which can be used, for example, to monitor the opening of the group board.

Technical specifications

excitement 230V, protection class II
Internal power consumption Approx. 0.1 W
Frequency 868.1 MHz
Range Up to 300 m - open terrain
IN input Low voltage, galvanically separated from mains
Working voltage 5 V
Max. external voltage 30V DC
Max. connection length 3 m
PU input Low voltage, galvanically separated from mains
Working voltage 5 V
Max. external voltage 30V DC
Max. connection length 3 m
TA input input for voltage control of the device Max. 230 V AC
Dimensions 68 x 96 x 18 mm, 1 DIN module
Operating temperature -20 to +60 ° C
IP class IP40
Installation environment Indoors
Model: JA-151TH

JA-151 TH is a wireless temperature gauge, from Jablotron. From the meter, data is sent, via the control panel, to the Web Self Service (WSS) on Cloud Jablotron. The measured dates are stored in WSS, and from here you can see temperature graphs and set up parameters for notifications about e.g. fluctuations in temperatures. These notifications can be obtained via SMS, push notification from the app or email. In addition, you can see the status on either the mobile app or on the website.

With these functions, the sensor is suitable for keeping track of refrigerated display cases, server rooms, frost protection of holiday homes, etc.

Please note that the wireless version is not recommended for freezers.

Technical specifications

excitement 1 piece. lithium battery CR2032 (3 V, 220 mAh)
Battery life Approx. 2 years at 100 daily activations
Frequency 868 MHz
Range Approx. 200 m - open terrain
Temperature accuracy + 0.5 ° C
Dimensions 55 x 27 x 16 mm
Installation environment Indoors
Model: JA-150G-CO

The JA-150G-CO is a wireless module that can be installed in an EI208W carbon monoxide detector and enables wireless connection to the JABLOTRON 100 system. The module can send information to the system, about alarm, deactivation and battery status in the detector. The module takes up one space in the system.

Technical specifications
excitement EI208W battery
Frequency 868.1 MHz, Jablotron protocol
Range Up to 300 m - open terrain
Operating temperature -10 to + 40 ° C
Dimensions 109x24x22 mm
Installation environment Indoors
Model: JA-188J

JA-188J is an assault and emergency call transmitter. However, it can also be used to control other devices e.g. opening the door, switching lights on / off or switching on / off an area, etc.

Through the control panel, it is possible to set which function you want the button to have. The default setting is either assault or on / off. The other functions can be found under units in F-link. There is also sabotage cash in the pressure and it also monitors the battery voltage.

Technical specifications

excitement Lithium ½ AA 3.6V / 1.2 Ah
Battery life ca. 3 years for 20 daily activations
Frequency 868 MHz
Range ca. 300 m - open terrain
Operating temperature -10 ° C to + 40 ° C
Dimensions 80 x 80 x 29 mm
Model: JA-187J

JA-187J is an assault transmitter that can be worn as either a wristwatch or around the neck (strap included in the package).

But in addition, it can also be used to control other devices if desired.

Technical specifications

excitement Lithium type CR 2032 (3.0V)
Battery life ca. 3 years with 1 daily activation
Frequency 868 MHz
Range ca. 50 m - open terrain
Operating temperature -25 to +50 c
IP Class IP-44
Model: JB-EXT-TH-R

JB-EXT-TH-R is a wireless outdoor temperature detector from Jablotron.

If you need wireless temperature measurement in outdoor or climatically demanding environments (IP 53), JB-EXT-TH-R makes this possible. It does this using an internal or external sensor. The internal sensor, which is part of the product, measures the temperature in a range from -25 to 60 ° C. If you need something that can measure temperatures on both gas, liquid or solids, in the range from -50 to 200 ° C, you must, however, have a JB-TS-PT1000, which is an external sensor (not included) .

The measured data is sent to MyJablotron, where it is analyzed and saved for later use. This could be for activating a selected PG output, SMS reporting when temperature limits are exceeded or for creating diagrams of the measured temperatures. All these features are programmable in the MyJablotron app.

Note that PG control is only assigned to a maximum of two thermometers per central.

Cloud Jablotron can notify if temperature limits are exceeded, display graphs of previously measured temperatures, and can be programmed to notify different people when different criteria are met - e.g. by temperature drop or rise.

JB-EXT-TH-R is thus optimal for monitoring temperatures in server rooms and refrigerated display cases, or for, for example, frost-proofing a holiday home.

Technical specifications
excitement 2 x lithium battery type CR123A (3.0 V / 1500)
Power consumption 15μ / 50mA
Battery life in dry environments 0-30C
- with internal sensor 5 years with 1 x CR123A - 10 years with 2 x CR123A
- with external sensor 2 years with 1 x CR123A - 4 years with 2 x CR123A
Low battery level info <2.4 V
Frequency 868 MHz Jablotron protocol
Range ca. 200 m (open area)
Temperature accuracy + 0.5C
Internal sensor measuring range -25 ° C to + 60 ° C
External sensor measuring range -50 ° C to 200 ° C
Operating temperature -25 ° C to + 60 ° C
Internal sensor accuracy ± 0.6 ° C
External sensor accuracy ± 1 ° C
Installation environment IP53 - indoors
Dimensions 90x110x35 mm
Weight 145g
Model: JB-TS-PT1000

JB-TS-PT1000 is an external temperature sensor for Jablotron's outdoor thermometers JB-EXT-TH-R and JB-EXT-TH-B. The sensor has a cable length of 3 meters, but can be extended up to 50. Its temperature measuring range goes from -50 ° C to +200 ° C, and it can also be used for both gas, liquid and solid masses. For installation environment IP 68.

Technical specifications

Measuring range -50 ° C to + 200 ° C
Ambient humidity 10% - 100%
Atmospheric pressure 70 to 106 k PA
The diameter of the house 4.6 ± 0.1 mm
The length of the house 24 mm
Electrical power 500 VAC according to EN 60730-1
Insulation resistance > 200 MΩ at 500 VDC, 25 ° ± 3 ° C
Type and length of supply cable Silicone, unshielded, 2 x 0.22 mm2; 3m
Model: JB-VA16

JB-VA16 is a valve adapter for Jablotron's wireless valve actuator JB-150N-HEAD, which is used for mounting on valve type VA16.

The adapter can be used with the valves Herz, Polytherm, KAN-Therm, Thermoval and Buderus.

There are five adapters in one package.

Technical specifications

Adapter type VA 16
Dimensions M 28 x 1.5
Model: JB-VA78

JB-VA78 is a valve adapter for Jablotron's wireless valve actuator JB-150N-HEAD, which is used for mounting on valve type VA78. It is this type of valve adapter that is to be used for Danish Danfoss RA valves.

There are five pieces. in a package.

Technical specifications

Adapter type VA 78
Valve Danfoss RA
Model: JA-118M

JA-118M BUS is a module with eight zone inputs, for magnetic switches. It is possible to program the zones individually, as single balanced, NC or special grid alarm;
where multiple activations are required before an alarm can be triggered. The module can be installed in the JA-190PL or KU-68 sockets.

Please note that the cable length must not exceed 100 m, between module and zone.

Technical specifications

excitement Via central bus BUS 12 V (9 - 15 V)
Standby consumption 5mA
Maximum total standby power on connected detector 50MA
Operating temperature -10 ° C to + 40 ° C
Dimensions 50 × 38 × 14 mm
Installation environment Indoors
Model: JA-116H

JA-116H BUS is a BUS-based expansion module from Jablotron, which is used for supply and connection of up to 16 third-party detectors with contact outputs.

The JA-116H can be installed directly in the JA-107K control panel and can be mounted in a JA-194PL multi-installation box in MEDIUM.

Technical specifications

Voltage via the control panel'S BUS 12 V (9 - 15 V)
Standby consumption 25 mA
Max. fobrug of 1 output from + U GND 100mA
Max. consumption of all outputs from + U GND 100mA
Operating temperature -10 to 40 ° C
Size 102 x 66 x2 0 mm
Indoor environment according to EN 50131-1
Model: JA-120Z

The JA-120Z is a wireless BUS device belonging to the JA-100 system. With this it is possible to extend the data bus by 2 x 500 meters per. JA-120Z unit. The unit has a built-in power supply of 2A, with battery back-up. The data bus can be a maximum of 2000 meters, so up to three JA-120Z can be mounted in a row. The data buses are galvanically isolated.

It is recommended that you install the JA-120Z in a PLV-CP-L enclosure.

The device supports from 7 to 18 Ah battery, depending on the type of mounting cabinet. It is also able to integrate with F-Link, with current status information and setting.

Technical specifications

Power supply (JA-83PWR power supply) 90-250 V AC
Spending 50VA
Powered by the BUS control panel 12V (9..15V)
Nominal for backup calculation 10 mA
Output voltage typically 13.7 V DC
Maximum load current 2 A
Galvanically insulated (test volt 4 kV)
Back-up battery 12 V. 7 - 18 Ah
Backup-type battey stay, gel
Low battery level ≤ 10.9 V
Maximum time to charge backup battery <72 h / 80% C and 18 Ah
PCB dimensions 102 x 66 x 14 mm
Installation environment Generally indoors
Operating temperature range -10 to +40 ° C
Operation humidity 75% RH, non-condensing
Model: JA-110N-DIN

JA-110N BUS is a PG output relay, for mounting on YOUR rail. It has a switch set (NO / NO / C) and can be loaded with a maximum of 230V / 16A (8A). The module is connected to the control panel's BUS and loaded into the control panel, where it takes up one unit space. It both communicates and is supplied by the central bus.

Supported up to 128PG with version or higher: FW: LY6211.03.1, HW: LY11003.

Please note that versions with lower HW / FW are only supported up to 32PG.

Technical specifications
Supply voltage via the control panel's BUS 12 V (9 - 15 V)
Consumption Relay closed 5 mA
Consumption Activated 45 mA
Maximum output relay load max. 16 A / 250 V
Max load max 8 A / 250 V
Minimum for activation 100 mA at 12 V DC or 1.2 W
Operating temperature -10 ° C to + 40 ° C
Dimensions 18 x 90 x 64 mm
Model: JB-110N

Jablotron 's JB-110N is a BUS equipped PG output module designed to provide a NO / NC / C contact set with a maximum load of 8A. For example, the JB-110N can be used to turn things on or off, such as lights or fans.

- The PG output is programmed with a DIP switch (1-128)
- Several controlled by the same PG outputs can be mounted.
- Communicates and is supplied via the control panel's BUS.
- The PG module fits in the mounting boxes JA-190PL, JA-194PL and JA-195PL.

Note that the JB-110N replaces the previous JA-110N module, and also that the device does not take up space in the system as it is not addressable.

Technical specifications
Voltage via the control panel'S BUS 12 V (9 ... 15 V)
Power consumption during backup (relay switched on / off) 5 mA / 45 mA
Power consumption with cable 45 mA
Max. excitement 250V AC / 24V DC
Ohms loaded (cosφ = 1) max. 16 A
Inductive (capacitive) charged (cosφ = 0.4) max. 8 A
Mine. accepted relay output current 0.5 W
Dimensions 70 x 38 x 20 mm
Operating temperature 10 ° C to + 40 ° C
Installation environment Indoors
Model: JB-111N

JB-111N is a BUS based PG output module, which is intended to provide a NO / NC / C contact set with a maximum of 8A in load.

- The PG output is programmed with a DIP switch (1-128)
- Several controlled by the same PG outputs can be mounted.
- The module communicates and is supplied via the control panel's BUS.
- The unit fits in the mounting boxes JA-190PL, JA-194PL and JA195PL.

Note that the JB-111N replaces the previous JA-111N module, and also that the device does not take up space in the system as it is not addressable.

Technical specifications

Voltage via the control panel'S BUS 12 V (9 ... 15 V)
Power consumption during backup (relay switched on / off) 5 mA / 25 mA
Power consumption with cable 25 mA
Max. excitement 50 V AC / 60 V DC
Max. power 2 A
Mine. power 10 mA
Dimensions 70 x 40 x 15 mm
Operating temperature -10 ° C to + 40 ° C
Installation environment Indoors
Model: JB-118N

The output module JB-118N is made to give signals status in eight areas.

Signal IW / EW alarms in the 8 areas
or status of 8 PG outputs.
- The module fits in a JA-19xPL box.
- The outputs are galvanically isolated from the bus
- The setting is made via a DIP switch (PG 1-128).

Note that this unit is not addressable and does not take up space in the control panel.

Technical specifications

Voltage via the control panel'S BUS 12 V (9 ... 15 V)
Power consumption during backup (relay switched on / off) 5 mA / 10m A
Power consumption with cable 10 Ma
Max. current from + U-output (electronic fuse) <100 mA (all connected devices must be included in the current calculations)
Dimensions 77 x 40 x 15 mm
Operating temperature -10 ° C to + 40 ° C
Installation environment Indoors
Model: JA-150N

The JA-150N is a wireless PG output module that copies the status of a selected PG output in the JA-100 system (PG1 to PG 32).
The PG module is addressed on the board via the 5 DIP switches.

Note that the module does not take up any space in the control panel.

Technical specifications
excitement 230 V AC / 0.5 W
Exits / terminals 1 PG output 3 x terminals (C, NO, NC)
Output relay Max. 16 A / 250 V
Operating temperature -10 ° C to + 40 ° C
Installation environment Indoors