facebook

Hikvision DS-2TD3017T-2 / V

Model: DS-2TD3017T-2/V
9.899,00  Incl. VAT
( 7.919,20  Excl. VAT )
Availability: In stock In stock - ships within 1 to 2 weekdays In stock In stock - ships within 1 to 2 weekdays
Do you have questions about the product? +45 70701009

Ingenious dual-lens thermal camera to secure an area against uninvited guests or fire.

  • Nothing remains unseen - discover them on the thermal - and recognize them on the visual image.
  • Be your own alarm center - human, vehicle or fire, get notified directly on the phone.
  • White spotlight and speaker welcome people or scare uninvited guests
  • Store events on a recorder or directly in the camera with a memory card.
Thermal  
Image Sensor VOx Uncooled Focal Plane Arrays
Resolution 160 × 120
Pixel Interval 17 μm
Response Waveband 8 μm to 14 μm
NETD ≤40 mK (@25°C, F# = 1.1)
Focal Length 1.8 mm
Focus Mode Athermalized
Field of View 90° × 66.4° (H × V)
IFOV 9.44 mrad
Image Frequency 50 Hz:25 fps
Aperture F 1.1
Min. Focusing Distance 0.1 m
Optical  
Image Sensor 1/5” Progressive Scan CMOS
Resolution 1600 × 1200
Focal Length 1.29 mm
Min. Illumination Color: 0.04 Lux @ (2.4, AGC ON)
Field of View 92.6° × 75.8° (H × V)
Aperture F 2.4
Compression Standard  
Video Compression H.264 (Baseline/Main/High Profile) /MJPEG/H.265
Video Bit Rate 256 Kbps to 16 Mbps
Smart Function  
Temperature Range -20 °C to 150 °C (-4 °F to 302 °F), 0°C to 550 °C (32 °F to 1022 °F)
Temperature Accuracy Max (± 2 °C, ± 2%)
Temperature Measurement Rules Display Max. and Min. temperature in live view; 3 temperature measurement rule types, 21 rules (10 points, 10 regions, and 1 line).
Image  
Main Stream Thermal channel: 25 fps (640 × 480) Optical channel: 25 fps (1600 × 1200)
Sub Stream Thermal channel: 25 fps (640 × 480) Optical channel: 25 fps (1600 × 1200)
Image Enhancement 3D DNR, EIS
Image Setting Rotate mode, brightness, contrast and AGC adjustable by client software or web browser
  Network
Alarm Trigger Video tampering alarm, Network disconnected, IP address conflict, Illegal login, HDD full, HDD error
Protocols IPv4/IPv6, HTTP, HTTPS, 802.1x, Qos, FTP, SMTP, UPnP, SNMP, DNS, DDNS, NTP, RTSP, RTCP, RTP, TCP, UDP, IGMP, ICMP, DHCP, PPPoE, Bonjour
General Function One-key reset, heartbeat, mirror, password protection, privacy mask, watermark, IP address filter
Interface  
Communication Interface 1,RJ45 Ethernet port 1,RS-485 interface
Alarm 1 input, 1 output
Thermographic Integration  
External Optics Correction Support Thermal Optical Transmittance and Manual Input External Optics Temperature; Support Calibration Coefficient calculation
Temperature Info. Of Thermographic Rule Real-time Output; Time Interval: 500 ms
Temperature Info. of Image Real-time Output; Default is 4 fps, 32 bit × 640 × 512 per frame; 16 bit and 32 bit are selectable
Capture Thermal Graphic 32 bit 160 × 120
Metadata Output Max. 25 fps (16 bit 160 × 120)
Image Display  
Image Fusion Fusion view of thermal view and overlaid details of the optical channel
Digital Zoom 2×, 4×
System Function  
Lighting Yes
General  
Menu language English
Power Supply 10-30 VDC, Max. 5 W PoE (802.3af, class 2)
Working Temperature and Humidity -20 °C to 50 °C (-4 °F to 122 °F) 95% or less
Protection level IP 67
Weight Approx. 335 g (0.74 lb)
Dimension 56 mm × 38.8 mm × 110 mm (2.20" × 1.53" × 4.33")

There is no reviews yet. Be the first to write us your opinion

Add review:

Thermal camera has 3 main advantages - protection of perimeter, protection against fire and monitoring of temperature. However, these cameras have another thing worth mentioning, namely an extra built-in camera. The series is therefore also called bi-spectrum because it captures both the thermal spectrum and the visual.

With its two lenses, the camera has a very good opportunity to protect against either fire and smoke development, against illegal intrusion and deviating temperature. The thermal lens ensures you very precise messages / alarms and the built-in relay makes it possible to connect the camera to most types of burglar alarms and control centers.

When setting up the camera, you choose whether it should be able to "Behavior analysis (perimeter protection) + measurement temperature" or "Fire detection + temperature measurement"

Behavioral analysis (perimeter protection)
You can choose what the camera should analyze, where it should do so and in what periods, as well as how it should react if a rule is violated

Protection against fire
Fire surveillance does not require much setup, as shown in the video below, as the camera has a setting for exactly this purpose.

The speaker makes it possible to warn people about the area about the impending fire or smoke development.

The thermal camera is often used to protect against arson on e.g. schools, institutions, factories, construction sites etc. as it can give notice long before a conventional fire alarm system. However, the camera must not be used as a replacement for a conventional and approved system, as it has not (yet) been approved by the fire authorities. But e.g. in a horse stable with hay and other combustible material, it could mean the difference between life and death as the fire could be detected in the infancy, which allows to handle the situation in time.

Video

The dynamic analysis responds to the evolution of the flames and heat.

Measurement of temperature :
The camera is also suitable for measuring temperatures, in cases that have nothing to do with fire - for example temperatures in server rooms, engine rooms, switchboards and more.