facebook
Model: JA-116H

JA-116H BUS is a BUS-based expansion module from Jablotron, which is used for supply and connection of up to 16 third-party detectors with contact outputs.

The JA-116H can be installed directly in the JA-107K control panel and can be mounted in a JA-194PL multi-installation box in MEDIUM.

Technical specifications

Voltage via the control panel'S BUS 12 V (9 - 15 V)
Standby consumption 25 mA
Max. fobrug of 1 output from + U GND 100mA
Max. consumption of all outputs from + U GND 100mA
Operating temperature -10 to 40 ° C
Size 102 x 66 x2 0 mm
Indoor environment according to EN 50131-1
Model: JA-120Z

The JA-120Z is a wireless BUS device belonging to the JA-100 system. With this it is possible to extend the data bus by 2 x 500 meters per. JA-120Z unit. The unit has a built-in power supply of 2A, with battery back-up. The data bus can be a maximum of 2000 meters, so up to three JA-120Z can be mounted in a row. The data buses are galvanically isolated.

It is recommended that you install the JA-120Z in a PLV-CP-L enclosure.

The device supports from 7 to 18 Ah battery, depending on the type of mounting cabinet. It is also able to integrate with F-Link, with current status information and setting.

Technical specifications

Power supply (JA-83PWR power supply) 90-250 V AC
Spending 50VA
Powered by the BUS control panel 12V (9..15V)
Nominal for backup calculation 10 mA
Output voltage typically 13.7 V DC
Maximum load current 2 A
Galvanically insulated (test volt 4 kV)
Back-up battery 12 V. 7 - 18 Ah
Backup-type battey stay, gel
Low battery level ≤ 10.9 V
Maximum time to charge backup battery <72 h / 80% C and 18 Ah
PCB dimensions 102 x 66 x 14 mm
Installation environment Generally indoors
Operating temperature range -10 to +40 ° C
Operation humidity 75% RH, non-condensing
Model: JA-110N-DIN

JA-110N BUS is a PG output relay, for mounting on YOUR rail. It has a switch set (NO / NO / C) and can be loaded with a maximum of 230V / 16A (8A). The module is connected to the control panel's BUS and loaded into the control panel, where it takes up one unit space. It both communicates and is supplied by the central bus.

Supported up to 128PG with version or higher: FW: LY6211.03.1, HW: LY11003.

Please note that versions with lower HW / FW are only supported up to 32PG.

Technical specifications
Supply voltage via the control panel's BUS 12 V (9 - 15 V)
Consumption Relay closed 5 mA
Consumption Activated 45 mA
Maximum output relay load max. 16 A / 250 V
Max load max 8 A / 250 V
Minimum for activation 100 mA at 12 V DC or 1.2 W
Operating temperature -10 ° C to + 40 ° C
Dimensions 18 x 90 x 64 mm
Model: JB-110N

Jablotron 's JB-110N is a BUS equipped PG output module designed to provide a NO / NC / C contact set with a maximum load of 8A. For example, the JB-110N can be used to turn things on or off, such as lights or fans.

- The PG output is programmed with a DIP switch (1-128)
- Several controlled by the same PG outputs can be mounted.
- Communicates and is supplied via the control panel's BUS.
- The PG module fits in the mounting boxes JA-190PL, JA-194PL and JA-195PL.

Note that the JB-110N replaces the previous JA-110N module, and also that the device does not take up space in the system as it is not addressable.

Technical specifications
Voltage via the control panel'S BUS 12 V (9 ... 15 V)
Power consumption during backup (relay switched on / off) 5 mA / 45 mA
Power consumption with cable 45 mA
Max. excitement 250V AC / 24V DC
Ohms loaded (cosφ = 1) max. 16 A
Inductive (capacitive) charged (cosφ = 0.4) max. 8 A
Mine. accepted relay output current 0.5 W
Dimensions 70 x 38 x 20 mm
Operating temperature 10 ° C to + 40 ° C
Installation environment Indoors
Model: JB-111N

JB-111N is a BUS based PG output module, which is intended to provide a NO / NC / C contact set with a maximum of 8A in load.

- The PG output is programmed with a DIP switch (1-128)
- Several controlled by the same PG outputs can be mounted.
- The module communicates and is supplied via the control panel's BUS.
- The unit fits in the mounting boxes JA-190PL, JA-194PL and JA195PL.

Note that the JB-111N replaces the previous JA-111N module, and also that the device does not take up space in the system as it is not addressable.

Technical specifications

Voltage via the control panel'S BUS 12 V (9 ... 15 V)
Power consumption during backup (relay switched on / off) 5 mA / 25 mA
Power consumption with cable 25 mA
Max. excitement 50 V AC / 60 V DC
Max. power 2 A
Mine. power 10 mA
Dimensions 70 x 40 x 15 mm
Operating temperature -10 ° C to + 40 ° C
Installation environment Indoors
Model: JB-118N

The output module JB-118N is made to give signals status in eight areas.

Signal IW / EW alarms in the 8 areas
or status of 8 PG outputs.
- The module fits in a JA-19xPL box.
- The outputs are galvanically isolated from the bus
- The setting is made via a DIP switch (PG 1-128).

Note that this unit is not addressable and does not take up space in the control panel.

Technical specifications

Voltage via the control panel'S BUS 12 V (9 ... 15 V)
Power consumption during backup (relay switched on / off) 5 mA / 10m A
Power consumption with cable 10 Ma
Max. current from + U-output (electronic fuse) <100 mA (all connected devices must be included in the current calculations)
Dimensions 77 x 40 x 15 mm
Operating temperature -10 ° C to + 40 ° C
Installation environment Indoors
Model: JA-150N

The JA-150N is a wireless PG output module that copies the status of a selected PG output in the JA-100 system (PG1 to PG 32).
The PG module is addressed on the board via the 5 DIP switches.

Note that the module does not take up any space in the control panel.

Technical specifications
excitement 230 V AC / 0.5 W
Exits / terminals 1 PG output 3 x terminals (C, NO, NC)
Output relay Max. 16 A / 250 V
Operating temperature -10 ° C to + 40 ° C
Installation environment Indoors
Model: JA-151N

The JA-151N is a 12 / 24VDC wireless relay that copies the status of a selected PG output in the JA-100 system (PG1 to PG 32).
The PG module is addressed on the board via the 5 DIP switches.

Note that this module does not take up any space in the control panel.

Technical specifications

excitement 12 - 16 VDC
Output relay Max. 1 A / 30 V DC
Exits / terminals 1 PG output 3 x terminals C, NC, NO
Operating temperature -10 ° C to + 40 ° C
Installation environment Indoors
Model: JA-192PL-A

JA-192PL-A is a universal can that can be used, for example, for Jablotron's JA-111 modules and their JA-151TH temperature detector.

Technical specifications
Color Light gray
Cable entry Use the deflection form and screw connection corresponding to the enclosure class
Dimensions 6.5 x 7 x 3.5 cm (H x W x D)
IP class IP65
Installation environment Outdoor
Model: JA-110T

JA-110T BUS is an insulator that can separate and protect a BUS connection in an unprotected area, against short circuit. The unit can be mounted in a JA-190PL box and is supplied through the control panel's BUS.

Be aware that it must not be addressed and therefore does not take up space in the exchange.

Technical specifications

excitement via the control panel's BUS 12 V (9 –15 V)
Standby consumption 5 mA
Maximum load 250 mA
Switch OFF 300 mA
Operating temperature -10 ° C to 40 ° C
Model: JA-110Z-B

JA-110Z-B can divide the system BUS into several branches. The print is square, has sloping terminal blocks and a large hole. The module can be mounted in a JA-190PL.

Technical specifications
Maximum voltage AC 42 V
Maximum voltage DC 60 V
Maximum current 2 A
Model: JA-110Z-D

The JA-110Z-D module can divide the BUS into several branches by removing the jumpers. The print is rectangular, has sloping elevator terminals, and center hole for cable insertion. The module is the same size as the JA-116H 8 x 4 terminals with elevator terminals. The module can be mounted in JA-194PL JA-106K PLV-CP-M / L and has a capacity for connection of up to 32 x CC-01.

Technical specifications
Maximum voltage 42 V DC
Maximum voltage 60 V AC
Maximum current 2 A
Model: JA-111I

JA-111I indicates that either on and off or PG output is activated (1-32). The indication takes place with multicolored LED in green, yellow, red, or blue.

Technical specifications

excitement 12 V (9 - 15 V)
LED ON consumption 4 mA
LED OFF consumption 0 mA
Operating temperature -10 to 40 ° C
Model: CC-01

CC-01 is a JA-100 installation cable, intended for the BUS installation, which can be walled directly into the wall.

The inner conductors of the cable match the terminal colors.

The cable is 300 m, each meter is marked for clarity. Comes in smart box that makes unrolling easy.

Technical specifications
1 x 2 x 24 AWG (0.5 mm) max. conducts DC resistance at 20 ° C 97 Ohm / km
1 x 2 x 20 AWG (0.8 mm) max. conducts DC resistance at 20 ° C 38 Ohm / km
Model: CC-02

CC-02 is an installation cable, intended for BUS installation.

The wires match the colors of the different terminals of the devices.

The cable is 300 m, each meter is marked for clarity. Comes in smart box that makes unrolling easy.

2 x 2 x 24 AWG (0.5 mm) max. conducts DC resistance at 20 ° C 97 Ohm / km

Model: CC-03

CC-03 is an installation cable for BUS installation. The wires match the colors of the different terminals of the devices. The cable is 250 m, each meter is marked for clarity. Comes in smart box that makes unrolling easy.

3 x 2 x 24 AWG (0.3 mm)
1 x 2 x 20 AWG (0.7 mm)

Model: CC-11

CC-11 is a fire-retardant installation cable, according to class B2CA. The cable is made for installations in places where many people move, such as hotels, schools and shops. The cable is more resistant to emissions of toxic gases or the spread of fire along cable bundles. The cable has a length of 200 m, each meter is marked and delivered in a cardboard box. The cable is made for JABLOTRON 100 alarm systems and the color of the conductors also matches the terminals in the terminal block from the JABLOTRON 100 series.

- 1 x 2 x 20 AWG (0.5 mm2)
- 1 x 2 x 24 AWG (0.5 mm2)
- EN 60332-1-2

To Top