Installation type |
Fixed installation |
Rated central voltage / frequency / fuse |
~ 230 V / 50 Hz, T200 mA fuse 250V, 5 x 20 mm, ~ 115 V / 60 Hz, T400 mA fuse 250V, 5 x 20 mm |
Operating voltage range |
~ 195 V ÷ 250 V, ~ 110 V ÷ 120 V |
Electric power supply |
Max 23 VA / 0.1 A |
Fuse class |
II |
Back-up battery |
12 V; 2.6 Ah max (lead acid) - 12 hours backup (2.6 Ah) |
Low battery voltage, fault indication |
11 V |
Maximum battery charging time |
48 ÷ 72 hours |
BUS voltage / max. Voltage rib |
12.0 ÷ 13.8 VDC / ± 100 mV |
Max. current consumption from the central BUS + RJ |
400 mA permanent (1000 mA for 5 minutes) |
LAN off |
125 mA - consumption of external modules |
LAN on |
85 mA - consumption of modules |
Max. Number of units |
20 |
Classification of the alarm system |
Safety class 2 / environmental class II |
Installation environment |
Indoors |
Operating temperature / humidity |
-10 ° C to + 40 ° C, relative humidity 75%, no condensation |
excitement |
Type A - primary supply with a charged backup battery |
Event log |
ca. 7 million recent events, incl. date and time |
System response to communication loss |
Error or tampering - according to the preset profile |
BUS |
Up to 10 sec. |
Wireless communication |
for 2 hours (report) |
Wireless communication |
for 20 min. blocking, system must be connected |
Invalid password response |
After 10 attempts with the wrong password, a tamper alarm is activated and according to the selected profile it blocks all control units for 10 min. |
ATS classification |
Supported ATS classes: SP2 - SP 5, DP2 - DP3 |
SPT |
Type Z |
Operating mode |
Examination |
Built-in LAN |
SP2 - SP5 (with IP protocol) |
JA-190Y |
SP2 - SP5 (with IP protocol) |
JA-190X |
SP2 (with Contact ID protocol) |
LAN + JA-190Y |
DP2 - DP3 (with IP protocol) |
LAN + JA-190X |
DP2 (with IP / CID protocol) |
ATS transfer protocols |
JABLO IP, SIA IP, Contact ID, JABLO SMS |
ATC protection against noise and data protection |
JABLOTRON protocol: Closed AES encryption with a key size of at least 128 bits - ANSI SIA DC-09.2012 protocol with 128 bit AES encryption |
LAN communication |
Ethernet interface CAT 5 (RJ-45) |
Dimensions (mm) |
268 x 225 x 83 |
Weight |
1450g |
The parameters of the JA-111R module |
868.1 MHz, <25 mW, GFSK <80 kHz |