Wireless smoke, heat and carbon monoxide alarm.

  • Alerts on smoke, rapid temperature rise or elevated CO levels.
  • Works both standalone and together with a hub.
  • Built-in 85 dB siren.
  • Can be controlled from your phone.
  • Easy installation.

When triggered, the alarm can both sound the siren and call you on the phone.

  • 695,00  Incl. VAT
    ( 556,00  Excl. VAT )

    Wireless smoke alarm that reacts to smoke and heat

  • 1.041,00  Incl. VAT
    ( 832,80  Excl. VAT )

    Wireless smoke alarm that reacts to smoke and heat

  • 718,00  Incl. VAT
    ( 574,40  Excl. VAT )

    Wireless smoke alarm that reacts to smoke and heat.

  • 1.048,00  Incl. VAT
    ( 838,40  Excl. VAT )

    Ajax KeyPad Plus - Wireless control panel with touch buttons and contactless access

  • 199,00  Incl. VAT
    ( 159,20  Excl. VAT )

    Pendant Mount for PTZ Dome Cameras - TR-CE45-IN

  • 189,00  Incl. VAT
    ( 151,20  Excl. VAT )

    Wall Bracket

  • 309,00  Incl. VAT
    ( 247,20  Excl. VAT )

    Ajax door and window contact in a sleek design

  • 439,00  Incl. VAT
    ( 351,20  Excl. VAT )

    Door and window contact with vibration and tilt sensor

  • 524,00  Incl. VAT
    ( 419,20  Excl. VAT )

    Ajax MotionProtect - Wireless motion sensor 

Technical specifications
Product type Wireless combined heat, smoke, and CO detector with replaceable batteries
Compatibility Compatible with Ajax hubs and radio signal range extenders
Communication technology Jeweller proprietary wireless technology
Two-way communication
Block encryption with floating key
Frequency hopping against radio interference and jamming
Frequency bands 866.0–866.5 MHz
868.0–868.6 MHz
868.7–869.2 MHz
905.0–926.5 MHz
915.85–926.5 MHz
921.0–922.0 MHz
Depends on sales region
Radio communication range Up to 1700 m in open space
Maximum effective radiated power Up to 20 mW
Radio signal modulation GFSK
Sensitive elements Smoke sensor
Heat sensor
CO sensor
Smoke detection Double-spectrum optical sensor
Recognizes smoke by particle size in the air
Does not react to water vapor
Smoke chamber Patented smoke chamber
Protects the smoke sensor from dust, dirt, and insects
Heat detection Class A1R heat detector requirements
High temperature alarm above 64 °C
Temperature spike alarm when temperature rises more than 10 °C in 1 minute or less
Requirements of EN 54-5 and BS 5446-2 standards
Carbon monoxide detection Chemical CO sensor
Alarm if accumulated CO dose is exceeded
CO alarm thresholds More than 50 ppm, no more than 90 minutes
More than 100 ppm, no more than 40 minutes
More than 300 ppm, no more than 3 minutes
Stops notifying when concentration drops to 50 ppm within one minute
Sensor life 10 years
After 10 years of operation, the detector must be replaced
Built-in siren 85 dB at a distance of 3 m
Sound notification of alarms
Active until the alarm reason is eliminated or notification is disabled
Interconnected fire alarm Primary interconnection via hub within 20 seconds
Fallback interconnection directly between detectors within 1 minute
Fallback interconnection requires supported firmware
LED indication Green LED indicates power
Yellow LED indicates malfunctions
Red LED indicates fire alarms
Front panel button Starts smoke chamber test in normal mode
Turns off detector sound notification during alarm or malfunction
Installation recommendations Designed for indoor installation only
SmartBracket mounting panel allows position adjustment after installation
Sabotage protection Tamper alarm on removal from surface or mounting panel
Device authentication against spoofing
Communication failure detection Within 15 minutes
Polling interval is fixed at 300 seconds
Detection time depends on Jeweller or Jeweller/Fibra settings
Power supply 2 × CR123A batteries
Pre-installed
Replaceable batteries
Battery life Up to 7 years
Operating temperature From 0 °C to +50 °C
Operating humidity Up to 80%
Protection class IP20
Dimensions 124 × 124 × 45 mm
Weight 274.5 g
Colours Black
White
Package contents FireProtect 2 RB (Heat/Smoke/CO) Jeweller
SmartBracket mounting panel
Installation kit
2 × CR123A batteries
Quick Start Guide
Warranty 24 months
Reservations are made for possible errors and changes in the specifications

There is no reviews yet. Be the first to write us your opinion

Add review:

Here you can see the compatibility between the various units and Hubs from Ajax
https://ajax.systems/tools/devices-compatibility/

Ajax FireProtect 2 RB - wireless smoke, heat and CO alarm

FireProtect 2 RB is a wireless fire detector that detects smoke, rapid temperature changes and elevated CO levels. When triggered the alarm immediately notifies the hub and can then alert you via the app, SMS or a phone call.

 

Reliable smoke detection

The sensor continuously monitors the air and reacts instantly to smoke. It uses an invisible beam of light inside a detection chamber — when smoke particles enter, the beam is broken, triggering the alarm. You avoid false alarms because the sensor is designed to distinguish real smoke from everyday elements like dust and steam from cooking.

 

Advanced heat detection

In addition to smoke, the alarm also responds to temperature changes, providing early warning even before visible smoke appears. The alarm activates automatically in two situations:

  • At temperatures above 64 °C
  • When temperature rises by more than 10 °C per minute

This is especially important for fires that develop rapidly without smoke in the early stage — for example electrical fires. The temperature threshold follows the A1R classification according to EN 54-5.

 

Carbon monoxide detection (CO)

FireProtect 2 RB has a built-in CO sensor that detects dangerous levels of carbon monoxide, also known as "the invisible killer".

CO levels are measured continuously, and the alarm is triggered at the following concentrations:

  • 50 ppm (0.005%) – after 90 minutes.
  • 100 ppm (0.01%) – after 40 minutes.
  • 300 ppm (0.03%) – after 3 minutes.

The alarm stays active until the CO level falls below 40 ppm.

 

Optical sensor

FireProtect 2 RB uses a dual-spectrum optical sensor with blue and infrared LEDs to accurately distinguish between smoke and other airborne particles like steam and dust.

The alarm process happens in three steps:

Detection: The sensor analyses the size and composition of airborne particles.

Verification: The HazeFlow 2 algorithm analyses data in real time. Short-term influences like cooking steam are ignored to avoid false alarms.

Alerting: When smoke is confirmed, the alarm is activated with an immediate notification.

 

Minimal maintenance

The smoke alarm has a patented smoke chamber that is resistant to dust and insects and therefore doesn't require regular cleaning. Regular function tests are recommended, but no other maintenance is necessary.

 

Interconnected alerts

When one smoke alarm is triggered, all connected alarms start at the same time. The system can be expanded with both outdoor and indoor sirens so neighbors are also warned during an alarm.

The system has two communication paths:

  • Primary hub connection: When activated, the alarm sends a message to the hub, which starts all connected smoke alarms within 20 seconds.
  • Backup connection: If the hub connection is lost, the alarms communicate directly with each other within 1 minute.

 

Easy installation

FireProtect 2 RB is installed in three simple steps:

  • Scan the QR code in the Ajax app.
  • Mount the device on the ceiling.
  • Finish the setup in the app.

 

Range

The range between the smoke alarm and the hub is up to 1,700 meters in open terrain.

 

Battery life

The sensor comes with 2 × CR123A batteries with a life of up to 7 years. Battery longevity is affected by several factors:

  • Frequency of use — frequent alarms reduce battery life.
  • Ambient temperature — low temperatures can affect battery performance.
  • Battery quality — higher-quality batteries generally last longer.

 

Tamper protection

The sensor sends an alarm to the hub if removal is attempted.

 

Dimensions and weight

  • Dimensions: 124 × 124 × 45 mm.
  • Weight: 274.5 g.
  • Available in: White or black.

 

Compatible Ajax hubs

FireProtect 2 RB is compatible with:

  • Hub (OS Malevich 2.15.4 or newer).
  • Hub Plus (OS Malevich 2.15.4 or newer).
  • Hub 2.
  • Hub 2 Plus.
  • ReX 2 signal repeater.

 

Technical information

  • Wireless range up to 1,700 m in open terrain.
  • Works both standalone and with an Ajax hub — the built-in siren also activates without a hub connection.
  • Built-in CO sensor warns at dangerous carbon monoxide levels (10-year lifespan).
  • Secure device authentication against tampering.
  • Tamper protection with alarm on attempted removal.
  • Two-way communication via the Jeweller protocol enables continuous tests and status updates.
  • Built-in protection against signal interference with jamming detection and frequency hopping.
  • Encrypted radio communication.
  • Built-in siren (85 dB) activated by smoke, heat or carbon monoxide.
  • Interconnected alerts — all devices in the system activate when a hazard is detected.
  • Temperature alarm at 64 °C or during rapid temperature rise.
  • Battery life up to 7 years (depending on use and environment).
  • Quick installation with SmartBracket mount without disassembly.
  • LED indicator and test button for manual function checks.